TitleProduct

Water Cooled Screw or Scroll Chiller

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2020-08-28 07:36

  • Browse the number:

    449

Send an inquiries

Company Profile

Nanjing RICOM Refrigeration Equipment Co., Ltd

By certification [File Integrity]

Contact:nanjingruihongkang(Mr.)  

Email:

Telephone:

Phone:

Area:Jiangsu

Address:Jiangsu

Website:http://www.oem-chiller.com/ http://nanjingruihongkang.fswangao.com/

Product Details


Product Description


The water-cooled chillers of Nanjing RICOM Refrigeration Equipment Co., Ltd. are divided into water-cooled screw chillers and water-cooled scroll chillers.

The main components of the water-cooled screw chiller use screw compressor. Its freezing outlet temperature range is 5 ℃ ~ 30 ℃. Semi-enclosed compressor is adopted, which is 20%-30% higher in energy efficiency than ordinary compressors. Its efficiency is high, maintenance is simple, capacity is accurately controlled, noise is low, and vibration is low. The refrigerating capacity of the water-cooled scroll chiller unit ranges from 124.9 kW to 358.4 kW, meeting different load requirements in various occasions. The unit has compact structure, small occupied area, simple pipeline design, only external water pipes are needed, and installation and maintenance are simple. It provides multiple protection functions such as high and low voltage protection, chilled water anti-freezing and icing protection, power supply phase sequence protection, lack of phase protection, insufficient water flow protection, compressor motor overheating, etc.



Product Principle



Product Characteristics



Water-cooled screw chiller

Water-cooled scroll chiller

Compressor

German "BIZEER" or Taiwan "HANBELL" screw type

American COPELAND compressor or Japan "PANASONIC"

Condenser and evaporator

All-copper shell tube type

All-copper shell tube type

Control system

Chinese and English interface LCD display, timer switch function, 25%-50%-75%-100% energy automatic adjustment function, Japan "FUJI" Electric or German "Schneider"

Chinese and English interface LCD display, timer switch function, automatic energy adjustment function, Japanese "FUJI" Electric or German "Schneider"

Structure

Semi- hermetic twin-screw compressor, simple structure design, few parts, twin-screw structure, high-precision mechanical structure of water-cooled screw chiller, all parts are uniform, so that friction resistance is minimized, and the finely-machined double helix is tightly engaged; Smooth, quiet and durable. Due to the differential pressure oil supply method, complicated oil circuit systems such as oil coolers and oil pumps are eliminated, which is easy to maintain.

The unit has a compact structure, small floor space, simple pipeline design, only requires an external water pipe, and is easy to install and maintain.

Functions

Compressor overload, coil overheating protection, high exhaust temperature protection, low discharge water temperature protection, frequent compressor start and stop protection, voltage abnormal protection, phase loss and reverse phase protection, oil pressure difference and many other protection and processing functions

Provide multiple protection functions such as high and low pressure protection, freezing water anti-freezing protection, power phase sequence protection, lack of phase protection, insufficient water flow protection, compressor motor overheating, etc.



Product Process


Nanjing RICOM Refrigeration Equipment Co., Ltd. adheres to the spirit of craftsmanship and creates high-quality products.


Product Parameters


Technical parameters of water - cooled screw chiller

Model

RC2-40W

RC2-50W

RC2-60W

RC2-80W

RC2-90W

RC2-100W

RC2-110W

Refrigerating capacity (Kcal/h)

122980/143/40.7

161422/187.7/53.4

173376/201.6/57.4

231942/269.7/76.7

288788/335.8/95.5

321554/373.9/106.4

346322/402.7/114.5

Refrigerant

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

Compressor Power (Hp)

40

50

60

80

90

100

110

Supply voltage

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

Energy regulation mode

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

Starting mode

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Piping of cooling water system

Pipe diameter

3"

3"

3"

3"

4"

4"

4"

Chilled drainage piping

Pipe diameter

3"

3"

3"

3"

4"

4"

4"

Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃


Model

RC2-120W

RC2-140W

RC2-150W

RC2-160W

RC2-180W

RC2-200W

RC2-220W

Refrigerating capacity (Kcal/h)

376594/437.9/124.5

457348/531.8/151.2

477988/555.8/158

528642/614.7/174.8

594518/691.3/196.6

692386/805.1/228.9

745190/866.5/246.4

Refrigerant

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

Compressor Power (Hp)

120

140

150

160

180

200

220

Supply voltage

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

Energy regulation mode

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

Starting mode

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Piping of cooling water system

pipe diameter

4"

5"

5"

5"

5"

5"

5"

Chilled drainage piping

pipe diameter

4"

5"

5"

5"

5"

5"

5"

Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃


Model

RC2-240W

RC2-280W

RC2-300W

RC2-320W

RC2-340W

RC2-360W

RC2-400W

Refrigerating capacity (Kcal/h)

811066/943.1/268.2

914696/1063.6/302.4

955976/1111.6/316

1057284/1229.4/349.6

1144832/1331.2/378.5

1189036/1382.6/393.2

1384772/1610.2/457.8

Refrigerant

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

Compressor Power (Hp)

240

280

300

320

340

360

400

Supply voltage

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

Energy regulation mode

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

25%-50%-75%-100%

Starting mode

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Y/▲

Piping of cooling water system

Pipe diameter

5"

6"

6"

6"

6"

8"

8"

Chilled drainage piping

pipe diameter

5"

6"

6"

6"

6"

8"

8"

Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃


Model

RC2-460W

RC2-560W

Refrigerating capacity (Kcal/h)

1490380/1733/492.8

1829392/2127.2/604.8

Refrigerant

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

Compressor Power (Hp)

460

560

Supply voltage

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

AC380V50HZ3PH/

AC440V50HZ3PH/

AC220V60HZ3PH

Energy regulation mode

25%-50%-75%-100%

25%-50%-75%-100%

Starting mode

Y/▲

Y/▲

Piping of cooling water system

Pipe diameter

8"

8"

Chilled drainage piping

pipe diameter

8"

8"

Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃


Technical parameters of water cooled scroll chiller

Model

SCW-05

SCW-08

SCW-10-Ⅱ

SCW-15-Ⅲ

SCW-20-Ⅱ

SCW-25-Ⅱ

Refrigerating capacity (Kcal/h)

15093

24148

30186

45279

60372

75465

Refrigerant

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

Compressor power (Hp)

5

8

10

15

20

25

Circulating pump power (Hp)

1

2

2

3

3

4

Piping of cooling water system

pipe diameter

1"

1.5"

1.5"

2"

2"

2.5"

Flow (m³/h)

3.4

5.5

6.85

9.3

12.7

15.1

Chilled drainage piping

pipe diameter

1"

1.5"

1.5"

2"

2"

2.5"

Flow (m³/h)

2.74

4.27

4.27

8.59

8.59

14.55

Supply voltage

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃


Model

SCW-30-Ⅱ

SCW-40

SCW-50

SCW-60

SCW-80

Refrigerating capacity (Kcal/h)

90558

120744

150930

181116

241488

Refrigerant

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

R22/R134A/

R404A/R407C

Compressor power (Hp)

30

40

50

60

80

Circulating pump power (Hp)

4

40HP and above are configured according to customer requirements

40HP and above are configured according to customer requirements

40HP and above are configured according to customer requirements

40HP and above are configured according to customer requirements

Piping of cooling water system

Pipe diameter

2.5"

3"

3"

4"

4"

Flow (m³/h)

18.5

24.5

30.2

36.2

48.2

Chilled drainage piping

pipe diameter

2.5"

3"

3"

4"

4"

Flow (m³/h)

14.55

22.06

22.06

42.2

42.2

Supply voltage

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

AC380V50HZ3PH

AC440V50HZ3PH

AC220V60HZ3PH

Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃


Customer Case


Water chillers can be widely used in plastics, electroplating, electronics, chemicals, pharmaceuticals, printing, food processing and other industrial refrigeration processes that require frozen water, or large shopping malls, hotels, factories, hospitals and other central air-conditioning projects. Areas where chilled water is used for centralized cooling.

My company has served many industries, has a wealth of industry application experience.



FAQ


Common problems when buying products

Q: How long has your company been established?

A: Our company was founded in 2014, but most of our engineers have been in the industry for over 15 years, and our boss has been in the industry for over 20 years.

Q: Is your company a trading company?

A: Our company is a trading company, but we have our own factory.

Q: What are your terms of payment?

A: T/T pays 30% in advance and 100% before delivery.

Q: How long is your delivery time?

A: 25-30 working days for standard products and 45 working days for non-standard customization

Q: How long is the warranty?

A: If the parts are broken or damaged, within 18 months from the date of leaving the factory.

These parts are provided free of charge by our company (except for wearing parts due to quality problems).


http://www.oem-chiller.com/